The Lumis 100 VPAP S is a personalized non-invasive ventilator tailored to support the patient’s respiratory condition. Vsync ensures excellent patient-ventilator synchrony, even in the presence of significant leaks.
TiControl™ allows patients to set minimum and maximum constraints on their optimal inspiratory time for encouraging spontaneous breath. Trigger and cycle settings can be adjusted based on the patient’s condition, with five trigger and cycle sensitivity levels available.
QuickNav enables low-touch treatment adjustment, easily switching between settings and monitoring screens by double-tapping the home button.
Climate Control Auto ensures automatic humidification when used with HumidAir™ heated humidifier and ClimateLineAir™ heated tube, simplifying the process without complicated menus to navigate.
With Ramp and Ramp Down features, Lumis offers additional comfort, easing patients into and out of each treatment session. Portea and Lumis 100 work together to deliver enhanced healthcare services to needy patients.
AIRCRAFT USE
ResMed confirms that the device meets the Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21, category M) for all phases of air travel.
dimensions
DIMENSIONS-(H x W x D): 116 mm x 255 mm x 150 mm
WEIGHT- 1268g
specifications
MODES -CPAP, S MODE
90W power supply unit
AC input range: 100–240V, 50–60Hz 1.0–1.5A, Class II 115V, 400Hz 1.5A, Class II (nominal for aircraft use)
DC Output: 24V 3.75A
Typical power consumption: 53W (57VA)
Peak power consumption: 104W (108VA)
Operating temperature: +5°C to +35°C
Operating humidity: 10 to 95% relative humidity, non-condensing
Operating altitude: Sea level to 8,500′ (2,591 m); air pressure range 1013 hPa to 738 hPa
Storage and transport temperature : -20°C to +60°C
Storage and transport humidity: 5 to 95% relative humidity, non-condensing
S.No. Features Lumis 100 VPAPA S Lumis 150 VPAP ST
Therapy modes
1 CPAP (continuous positive Airway pressure) Present Present
2 S (Spontaneous) Present Present
3 T (Timed) Absent Present
4 ST(Spontaneous-Timed) with optionaliBR Absent Present
5 PAC(Pressure Assist-Control) Absent Present
6 iVAPS with optional Auto EPAP Absent Present
Comfort and simplicity features
1 Vsync Present Present
2 Ticontrol Present Present
3 Trigger and cycle Present Present
4 Ramp Present Present
5 Ramp down Present Present
6 Climate Control Auto Present Present
7 Essentials mode Present Present
Data management
1 ResScan Present Present
condition used for
COPD (Chronic Obstructive Pulmonary Disease)
Sleep apnea
Lung disease
Order Medical Service
Please enter your details and we will reach out to you as soon as we can